What was found
LT EXTERIOR FUSELAGE STA 633 APPROX AND BETWEEN STR 10 & 11L IS DENTED / MEASURED DENT AT STA 633 BETWEEN 10L & 11L, FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO WINDOW CUTOUT REF B 757 SRM 53-00-01 NRC 200842.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT EXTERIOR FUSELAGE STA 633 APPROX AND BETWEEN STR 10 & 11L IS DENTED / MEASURED DENT AT STA 633 BETWEEN 10L & 11L, FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO WINDOW CUTOUT REF B 757 SRM 53-00-01 NRC 200842.