What was found
DURING NON ROUTINE CHECK, FRAME 1 BULKHEAD WEB DAMAGED BY BIRD STRIKE TRIMMED OUT DAMAGED WEB. HFEC NO CRACKS. FABRICATED .063" WEB SECTION AND .071" 2024-T3 WEB DOUBLER. DRILLED AND INSTALLED PER ER/A 497863-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING NON ROUTINE CHECK, FRAME 1 BULKHEAD WEB DAMAGED BY BIRD STRIKE TRIMMED OUT DAMAGED WEB. HFEC NO CRACKS. FABRICATED .063" WEB SECTION AND .071" 2024-T3 WEB DOUBLER. DRILLED AND INSTALLED PER ER/A 497863-14.