What was found
DURING LINE CHECK MAINTENANCE FOUND EMERGENCY FLOOR TRACK LIGHTS IN ROWS 21 AND 22 INOP. MAINTENANCE REPAIRED BROKEN WIRE FOR LIGHTS AT ROWS 21 & 22. OPERATION OF LIGHTS CHECK OK PER WDM 33-51-13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.