What was found
DURING INSPECTION AT BS 1000 S38R FORWARD BATHTUB FITTING, FOUND ONE FASTENER HOLE CRACKED. MAINTENANCE REPLACED BATHTUB FITTING, PER WORKCARD NR 5312-01044-04B FOR WORK DETAILS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION AT BS 1000 S38R FORWARD BATHTUB FITTING, FOUND ONE FASTENER HOLE CRACKED. MAINTENANCE REPLACED BATHTUB FITTING, PER WORKCARD NR 5312-01044-04B FOR WORK DETAILS.