What was found
MAIN CABIN AFT UTILITY AREA BETWEEN FR 68-FR 69 ST +Y512 FLOOR SUPPORT CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 102. REMOVED AND REPLACED FLOOR SUPPORT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN AFT UTILITY AREA BETWEEN FR 68-FR 69 ST +Y512 FLOOR SUPPORT CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 102. REMOVED AND REPLACED FLOOR SUPPORT.