What was found
AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR64 TO FR66 -Y765 2 HARD POINT HOLES CORRODED. BLENDED AREA. FOUND TO BE OUT OF LIMITS. REMOVED FLOORBEAM IAW A319 SRM 51-42-11. RECEIVED NEW FLOORBEAM. INSTALLED NEW FLOORBEAM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR64 TO FR66 -Y765 2 HARD POINT HOLES CORRODED. BLENDED AREA. FOUND TO BE OUT OF LIMITS. REMOVED FLOORBEAM IAW A319 SRM 51-42-11. RECEIVED NEW FLOORBEAM. INSTALLED NEW FLOORBEAM.