What was found
FWD ENTRY DOOR AREA TRACK CORROSION STA 225 LBL 5. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER MD80 SRM 53-04. FABRICATED TRACK PER MD80 SRM 53-14-2 AND INSTALLED PER TRACK AT STA 225 LBL 5 IAW MD80 SRM 51-30-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD ENTRY DOOR AREA TRACK CORROSION STA 225 LBL 5. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER MD80 SRM 53-04. FABRICATED TRACK PER MD80 SRM 53-14-2 AND INSTALLED PER TRACK AT STA 225 LBL 5 IAW MD80 SRM 51-30-05.