What was found
FLOOR SUPPORT BTW FR64 TO FR66 Y1292 UPPER FLANGE AND HOLES CORRODED. BLENDED AREA IAW SRM 51-74-00 L=2.0 INCH W=1.0 INCH D=.075 INCH. ORIG. .087 INCH OUT OF LIMIT IAW SRM 53-41-15. REMOVED AND INSTALLED NEW FLOOR SUPPORT BEAM IAW SRM 51-42-11.