As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT BETWEEN FR 64 TO FR 68 Y1292 UPPER FLANGE AND HOLES CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. ORIG MAT. .087 DAMAGE DIM. L=1.0 INCH W=.496 INCH D=.058 INCH. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-42-11.