What was found
RUDDER LEADING EDGE LEFT SIDE (3 INCH FROM BOTTOM) HAS COMPOSITE DAMAGE (CRACK). SANDED CLEANED PREPPED AREA AND BONDED COMPOSITE REPAIR MATERIALS PER A319 SRM 55-41-00 FIG 212 PARA 9 (L).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RUDDER LEADING EDGE LEFT SIDE (3 INCH FROM BOTTOM) HAS COMPOSITE DAMAGE (CRACK). SANDED CLEANED PREPPED AREA AND BONDED COMPOSITE REPAIR MATERIALS PER A319 SRM 55-41-00 FIG 212 PARA 9 (L).