What was found
AFT CABIN FLOOR SUPPORT BETWEEN FR 68 TO FR 69 LT Y1292 UPPER FLANGE AND HARD PT HOLES HAS CORROSION. BLENDED DAMAGED AREA IAW SRM 51-74-00. ORIG MAT THICKNESS 0.157 INCH L .005 W .173 D .060. REMAINING MAT. .097 INCH. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11. TRANSFERED THREE HARDPOINTS AND ONE BRACKET IAW SRM 51-42-11. LOCATED AND DRILLED FASTENER HOLES IAW SRM 51-44-11. TREATED AND PRIMED FASTENER HOLES IAW SRM 51-21-11. INSTALLED FLOOR SUPPORT IAW SRM 51-42-11. PAINTED FASTENER IAW SRM 51-75-12. STRINGER 645112 BFM