What was found
DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT Y512 HAS CORROSION ABOVE FR 66. BLENDED CORROSION IAW SRM 51-74-00, L=1.5 INCH W=1.0 INCH D=.025 INCH. REPLACED FLOOR SUPPORT PROFILE IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT Y512 HAS CORROSION ABOVE FR 66. BLENDED CORROSION IAW SRM 51-74-00, L=1.5 INCH W=1.0 INCH D=.025 INCH. REPLACED FLOOR SUPPORT PROFILE IAW SRM 51-42-11.