What was found
DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT -Y1292 HAS 5 AREA WITH EXFOLIATION BETWEEN FR 68 AND FR 69. REMOVED CORROSION IAW SRM 51-74-00 L=1.5 INCH W=1.0 INCH D=.060 INCH. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT -Y1292 HAS 5 AREA WITH EXFOLIATION BETWEEN FR 68 AND FR 69. REMOVED CORROSION IAW SRM 51-74-00 L=1.5 INCH W=1.0 INCH D=.060 INCH. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.