DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT -Y1292 HAS 7 AREAS WITH CORROSION BETWEEN FR 66 AND FR 68. REMOVED CORROSION IAW SRM 51-74-00 L=2 INCH W=1.25 INCH D=.055 INCH. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.