What was found
DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT -Y1292 HAS 3 AREAS WITH CORROSION BETWEEN FR 65 AND FR 66. REMOVED CORROSION IAW SRM 51-74-00 L=1.5 INCH W=.5 INCH D=.030 INCH. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTIONS FOUND AFT UTILITY FLOOR SUPPORT -Y1292 HAS 3 AREAS WITH CORROSION BETWEEN FR 65 AND FR 66. REMOVED CORROSION IAW SRM 51-74-00 L=1.5 INCH W=.5 INCH D=.030 INCH. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.