As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FORWARD UTILITY AREA FLOOR SUPPORT BETWEEN FR 12 TO FR 16 LT Y503.2 UPPER FLANGE SURFACE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. CHECK LIMITS ORIG MAT .163 INCH L=3.05 INCH W=1.07 INCH D=.115 INCH MAT REMAINING .048 INCH TO BE OUT OF LIMITS IAW SRM 51-11-14 FIG 106. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. LOCATED AND DRILLED FASTENER HOLES IAW SRM 51-44-11. INSTALLED FLOOR SUPPORT IAW SRM 51-42-11.