What was found
AFT CABIN FLOOR SUPPORT BTW FR65 RT -Y1292 UPPER FLANGE CORRODED. BLENDED AREA IAW SRM 51-74-00. CHECK LIMITS ORIG MAT THICK .087 INCH. AFTER BLENDED MAT LOSS D=.070 INCH, L=2.300 INCH W=.750 INCH. MATERIAL REMAINING .017 INCH FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15 FIG 1. REMOVED FLOOR SUPPORT IAW SRM 51-42-11, FROM FR 64 TO FR 66. INSTALLED NEW FLOOR SUPPORT FROM FR 64 TO FR 66 -Y1292 IAW SRM 51-42-11. TREATED AND PRIMED HOLES IAW SRM 51-21-11 AND PAINTED FASTENERS IAW SRM 51-75-12.