What was found
DURING INSPECTIONS, FOUND AFT UTILITY AREA CABIN FLOOR SUPPORT BEAM BTW FR 68 TO 69 Y1292 HAS CORROSION AND SEVERAL RIVETS BROKEN. BLENDED AREA IAW SRM 51-73-00. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTIONS, FOUND AFT UTILITY AREA CABIN FLOOR SUPPORT BEAM BTW FR 68 TO 69 Y1292 HAS CORROSION AND SEVERAL RIVETS BROKEN. BLENDED AREA IAW SRM 51-73-00. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.