What was found
DURING INSPECTIONS, FOUND LIGHTNING STRIKE AT FR48 BET STR 22L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. REPLACED FASTENER PER SRM 53-41-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTIONS, FOUND LIGHTNING STRIKE AT FR48 BET STR 22L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. REPLACED FASTENER PER SRM 53-41-11.