What was found
DURING INSPECTION, FOUND LIGHTNING STRIKE AT FR 54 BET STR 22L AND 23L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11 (ID201079). PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. INSTALLED FASTENER PER SRM 53-41-11.