What was found
AFT UTILITY AREA RT SIDE BTW FR 68 TO FR 69 STRINGER 23R SHEAR PLATE CRACKED. REMOVED SHEAR PLATE AND SUPPORT IAW SRM 51-42-11. LOCATED AND DRILLED NEW SHEAR PLATE IAW SRM 51-44-11. INSTALLED NEW SHEAR PLATE IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA RT SIDE BTW FR 68 TO FR 69 STRINGER 23R SHEAR PLATE CRACKED. REMOVED SHEAR PLATE AND SUPPORT IAW SRM 51-42-11. LOCATED AND DRILLED NEW SHEAR PLATE IAW SRM 51-44-11. INSTALLED NEW SHEAR PLATE IAW SRM 51-42-11.