What was found
DURING EDDY CURRENT INSPECTION FWD SERVICE DOOR JAMB FORWARD UPPER CORNER SECT 01B, CRACK INDICATIONS (1 ON SKIN, 2 SUB-SURFACE) WERE DETECTED EMANATING FROM FASTENERS AS MARKED, ALL CRACKS APPROX 1/8 INCH IN LENGTH. REPAIRED FWD SERVICE DOOR JAMB FWD UPPER CORNER.