AFT CABIN FRAME 68-69 FLOOR SUPPORT Y1292 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, DAMAGE OUT OF LIMITS IAW SRM 53-00-14. REMOVED FLOOR SUPPORT, SPLICES, HARD POINT AND BRACKET IAW SRM 51-42-11, FOUND ONE SPLICE AND HARD POINT CORRODED AND GOUGED. NEW FLOOR SUPPORT, SPLICE AND HARD POINT, LOCATED AND DRILLED AND INSTALLED IAW SRM 51-42-11.