As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT UTILITY AREA FLOOR SUPPORT -Y1292 BETWEEN FR 67 AND FR 68 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 & FOUND TO BE OUT OF LIMITS. REMOVED FLOOR SUPPORT BEAM IAW SRM 51-42-11. NEW FLOOR SUPPORT LOCATED, AND DRILLED IAW SRM 51-44-11. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-42-11.