What was found
AFT UTILITY AREA FLOOR SUPPORT, BETWEEN FR 68-69 Y1292 UPPER FLANGE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA FLOOR SUPPORT, BETWEEN FR 68-69 Y1292 UPPER FLANGE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11.