LINE CHECK FOUND "EPSU UNIT AFT L" ON CIDS PANEL. BITE TEST ON UNIT 13WL HAS UNIT FAIL FAULT LIGHT. R & R EPSU 13WL IAW AMM 33-51-38. OPS CHECKED GOOD. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LINE CHECK FOUND "EPSU UNIT AFT L" ON CIDS PANEL. BITE TEST ON UNIT 13WL HAS UNIT FAIL FAULT LIGHT. R & R EPSU 13WL IAW AMM 33-51-38. OPS CHECKED GOOD. OK FOR SERVICE.