What was found
MAIN CABIN FLOORBEAM UPPER SURFACE CORRODED STA 365.25 BL 0 -RBL 63. REMOVED CORROSION ON FLOORBEAM & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 ALLOWABLE DAMAGE 1, PG 104, FIG 101 DETAIL III. CUTOUT UPPER FLANGE OF FLOORBEAM, FROM LBL 9.5-RBL 70 WITH CUTOUT DIMENSIONS OF L=79.5 X W=2.0. REPAIRED DAMAGED AREA IAW SRM 53-00-51, REPAIR 3, PG 203, FIG 201, TABLE I AND ERA 488913-14 MA REV B.