As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON MAIN CABIN FLOORBEAM AT BS 1640 LBL 3 TO RBL 3. REMOVED CORROSION AT MAIN CABIN FLOORBEAM & FOUND OUT OF LIMITS IN REF SRM 53-00-51 ALLOWABLE DAMAGE 1, FIG 101. REPAIRED UPPER TEE IN REF SRM 53-00-51, REPAIR 3. COMPLETED INSPECTED.