What was found
DURING INSPECTION, FOUND AFT UTILITY RT DOOR SILL HAS 4 AREAS OF CORROSION BETWEEN FR 66 AND FR 68 FLOOR SUPPORT SECTION AS MARKED. ACCOMPLISHED ANGLE REPAIRS AT BOTH FR 66 & FR 68 IAW SRM 53-41-14, FIG 201 & ER/A'S 506753-14 & 506756-14. REF LP 0608213 FOR FOLLOW-ON INSP.