What was found
DENT ON FUSELAGE FRAME AT AFT CARGO COMPARTMENT ST 1500, BETWEEN STRINGER 25L AND 26L. REMOVED PRODUCTION SPLICE AND 2EA STRINGER CLIPS AT STA 1500, STR. 25-26L IAW SRM 51-40-02, PG 31, FIG 8. CUT OUT DAMAGE ON FRAME 0.9" X 1" AT STA 1500 IAW SRM 53-00-07. REPAIR NR 5, FIG 201. FABRICATED REPAIR ANGLE AND 2EA CLIPS, TRATED AND PRIME AND INSTALLED ALL PARTS IAW SRM 53-00-07 REPAIR NR 5, FIG 201. THIS IS A CATEGORY B REPAIR.