As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FORWARD UTILITY AREA FLOORBEAM BETWEEN FR16 TO FR20 Y1292 HARD POINT HOLE INSIDE AND UPPER FLANGE BEAM CORROSION. SSI 531189. BLENDED AREA IAW SRM 51-74-00 L=2.0 W=1.10 D=.040 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 102. R & R FLOOR BEAM IAW SRM 51-42-11 AND SRM 51-44-11. RETAIN FOR RECORDS.