What was found
AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 66 TO FR 68 Y-1292 UPPER AND LOWER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, DIMENSIONS L=1.0" W=.090" D.060", ORIG THICK .087". FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, FIG 1. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-42-11.