What was found
FWD LEFT SIDE OF FUSELAGE AT FR9 APPROX STR 21L DENTED. NR 200/10. DENT IS OUT OF "NEARNESS/FORM" CRITERION IAW SRM 53-11-11, FIG 104 DIM A= 1.1", B=.400", D=.031", T= .047". CUT OUT DAMAGED AREA IAW SRM 53-11-11, FIG 212, DIM. L=2.740" W=1.210". HFEC CUT OUT IAW NTM 51-10-08. NO CRACK NOTED. FABRICATED DOUBLER AND FILLER IAW SRM 53-11-11 FIG 212, MACHINED DOUBLER IAW SRM 53-11-11, FIG 212. INSTALLED FILLER AND DOUBLER IAW SRM 53-11-1, FIG 212 AND SRM 51-42-11. FIRST INSPECTION AFTER REPAIR EMBODIMENT 60,000 FC IAW SRI 53-11-11-2-003-00.