What was found
FUSELAGE SKIN HAS CRACKED AND WORKING FASTENERS STA 1439 BETWEEN LONGERON 2R AND 4R. HFEC INSP. VERIFIED (2EA) CRACKS APPROX 1" LONG BETWEEN L3R AND L4R, CUT OUT 2 DAMAGE AREAS. CUT OUT DIMENSIONS IS 2", NDT CHECK FOR CRACKS AND OPEN HOLE, FABRICATED DOUBLER AND 2EA FILLERS. INSTALLED REPAIR DOUBLER AND 2EA FILLERS IAW SRM 53-04, FIG 27, PG 143.