What was found
DURING INSPECTION, FOUND FORWARD CABIN FLOOR SUPPORT BETWEEN FR 18 TO FR 21 Y254 UPPER FLANGE HAS CORROSION & SCRIBE LINE AS MARKED. REMOVED CORROSION IAW SRM 51-74-00, DIM L=2.7" W= 1.5" D= .045" ORIG MAT .079" FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. REPLACED Y254 FLOOR SUPPORT FR 12-24, PN D5311281820401 IAW SRM 51-42-11.