What was found
DURING INSPECTION, FOUND LOWER FUSELAGE AT STR 31L BET FR 20 AND 21 DENTED .018" DEEP .437" WIDE OUT OF EDGE LIMITS IAW SRM 53-00-11, PG 101-LP 2472695. DENT FOUND OUT LIMITS IAW SRM 53-11-11. CUTOUT DAMAGE L=1.90 0"W=1.0"& FABRICATED DOUBLER AND REPAIR PARTS IAW SRM 53-11-11, FIG 213. INSTALLED DOUBLER AND REPAIR PARTS IAW SRM 53-11-11. 213. INSPECT AREA AT 60000FC IAW SRI 53-11-11, TABLE 204.