What was found
DURING SERVICE CHECK FOUND 4 LOWER EMERGENCY EXIT SIGNS AT OVERWING EXITS NOT ILLUMINATED. TROUBLESHOT IAW FIM 33-51 TO FUSES IN EMERGENCY LIGHT POWER SUPPLIES ASSOCIATED WITH SIGNS. REPLACED FUSES. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SERVICE CHECK FOUND 4 LOWER EMERGENCY EXIT SIGNS AT OVERWING EXITS NOT ILLUMINATED. TROUBLESHOT IAW FIM 33-51 TO FUSES IN EMERGENCY LIGHT POWER SUPPLIES ASSOCIATED WITH SIGNS. REPLACED FUSES. OPS CHECKED GOOD.