What was found
DURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 162EF MULTIPLE PUNCTURES. SLOPE PANEL FABRICATED IAW FIG 209, DIAMETER OF PUNCTURE .350 AREA (1) .400 AREA (2) FOUND OUT OF LIMITS IAW SRM 53-02-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.