What was found
BS 332, RBL 2-24, FLOORBEAM FOUND CORROSION. CORROSION REMOVED IAW SRM 51-10-02 AND FOUND EXCEED LIMITS IAW SRM 53-00-04, FIG 101. ORIGINAL THK=0.050", L=4", W=2", MATERIALS REMOVED=0.028". FLOORBEAM R & R IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 332, RBL 2-24, FLOORBEAM FOUND CORROSION. CORROSION REMOVED IAW SRM 51-10-02 AND FOUND EXCEED LIMITS IAW SRM 53-00-04, FIG 101. ORIGINAL THK=0.050", L=4", W=2", MATERIALS REMOVED=0.028". FLOORBEAM R & R IAW SRM 51-40-02.