What was found
DURING INSPECTION, FOUND LT WING SLAT TRACK NR 6, CLOSING PLATE CHAFING WITH SLAT LOWER T/E. BLENDED OUT CHAFE DAMAGE IAW SRM 51-73-00. DIM OF REWORK L=3.2", W=.25", D=.012". FOUND OUT OF LIMITS IAW SRM 57-40-00, FIG 106. ACCOMPLISHED DVI IAW NTM 51-90-00 AND HFEC IAW NTM 51- 10-08, NO ADDITIONAL DISCREPANCIES NOTED. COMPLIED WITH FINAL ER/A 509268-14 REV. ORIGINAL SECTION I PERMANENT REPAIR.