What was found
FLOOR SUPPORT BEAM +Y765 AT FR66 IS CORRODED. BLENDED AREA IAW A319 SRM 51-74-00 L=4.0" W=1.3" D=0.065". FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 101. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW A319 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT BEAM +Y765 AT FR66 IS CORRODED. BLENDED AREA IAW A319 SRM 51-74-00 L=4.0" W=1.3" D=0.065". FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 101. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW A319 SRM 51-42-11.