FLOOR SUPPORT BEAM +Y765 AT FR66 AND FR68 IS CORRODED AT SEVERAL AREAS. BLENDED AREA IAW A319 SRM 51-74-00 L=2.20" W=1.30 D=0.095". FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 101. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW A319 SRM 51-42-11.