What was found
FLOOR SUPPORT BEAM +Y512 AT FR68 HAS CORROSION. BLENDED AREA IAW A319 SRM 51-74-00. CORRODED AREA MEASURE L=.450 W=.150 D=.040. OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 102. REMOVED & REPLACED FLOOR SUPPORT IAW A319 SRM 51-42-11. RETAIN FOR RECORDS.