As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT BEAM -Y1292 FR64 TO FR66 BOTH FWD AND AFT END CORRODED. REMOVED CORROSION IAW A319 SRM 51-74-00 ORIG MAT .095" REWORK DIMENSIONS L=3.5" W=1.2" D=.070". FOUND TO BE OUT LIMITS IAW A319 TRM 53-41-15. REMOVED AND REPLACED FLOORBEAM SUPPORT IAW A319 SRM 51-42-11.