As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT BEAM -Y1292 FR68 CORRODED. REMOVED CORROSION IAW A319 SRM 51-74-00 ORIG MAT .150. REWORK DIMENSIONS L=2" W=3" D=.075". FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-41-15. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW A319 SRM 51-42-11.