What was found
DURING INSTALLATION OF #0 RT SLAT NR 2 TRACK FOUND I/B FWD RIB FWD/LWR EDGE GOUGED. BLENDED GOUGE AT #0 RT SLAT NR 2 TRACK INBD RIB FWD LOWER EDGE AS PER MD-90 SRM 57-00-01 PG 3. NO CRACKS NOTED AS PER NDT S.P.M. 06-10-01-01-001 MAT LOSS .040 LENGTH 2.65 AT I/B SIDE FOUND LOBE WITHIN LIMITS AS PER MD-90 SRM 57-00-01 AND ERA 498700-14 PG 1-3. TREATED AND PRIMED AS PER MD-90 SRM 51-10-03 VOL ID REPAIR AS PER DPS 900-5-1 NO.4 (ERA 498700-14).