As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD MAIN CABIN FLOOR SUPPORT DUMMY BEAM AT FR16+Y503 HAS CORRISION. SSI 531189. REMOVED CORROSION IAW A319 SRM 51-74-00. CHECK LIMIT L=3.3 W=1.8 IN. D=.028 IN. FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-11-14 FIG 106. REMOVED AND REPLACED FWD MAIN CABIN FLOOR SUPPORT DUMMY BEAM AT +Y503 FROM FR 12 TO FR16 IAW A319 SRM 51-42-11.