As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CABIN FLOOR SUPPORT +Y765 BET FR66 TO FR68 CORRODED. SSI 534147. REMOVED AND REPLACED FLOORBEAM. FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 L=3.00 W=1.00 D=0.125 ORIG MAT. THICKNESS .125. INSTALLED FLOOR SUPPORT IAW A319 SRM 51-42-11. TOP COATED FASTENER HEAD IAW A319 SRM 51-75-12. RETAIN FOR RECORDS.