What was found
DURING HFEC OPEN HOLE INSP ON AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER, HOLES NR 2 AND NR 4 FOUND WITH CRACK INDICATION. AFT CARGO DOOR CUTOUT UPPER FORWARD CORNER WORK CARRIED OUT AS PER PRI 500187-14D REV 0, 1, 2 AND 3 DATED 12 MAR12 TIME 1100HRS. COMPLIED WITH ER/A 500187-14 REV A COMPLIED AND ACCOMPLISHED. DATED 26MAR12.