As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CABIN FLOOR SUPPORT +Y1292 BETWEEN FR 66 TO FR 68 CORRODED. SSI 534147. BLENDED AREA IAW A319 SRM 51-73-00 L=.087"W=1.2"D=.027"ORG MAT .087" FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 102. REMOVED FLOOR SUPPORT BEAM IAW A319 51-42-11. LOCATED AND DRILLED NEW FLOOR SUPPORT BEAM IAW A319 SRM 51-44-11. INSTALLED NEW FLOOR SUPPORT BEAM IAW A319 SRM 51-42-11. PAINTED FASTENERS IAW A319 51-75-12.